The top of the Sperm Quality Analyzer line
Automatic results in 75 seconds
WHO semen parameters are reported in addition to derived and total/ejaculate parameters - all these SQA-V reported parameters result in a comprehensive semen analysis assessment
Automatically reads fresh, frozen, washed and post-vasectomy samples
On-screen visualization of the semen sample on the video screen of the
SQA-V or on a PC display (with counting grid and image freezing) using a standard laboratory slide or an SQA-V capillary
Variable optical magnification from x300 to x500
Video clips can be recorded using V-Sperm III software
A complete semen analysis report can be automatically printed-out
A “High Sensitivity” test mode for oligo-, asteno- and azoospermia determination, and vasectomy validation
Disposable testing capillary is biologically safe and can be conveniently used in virtually any testing environment
PC-compatible
Patient test results, images and clips can be downloaded to a PC using V-Sperm III software
Parameters tested
Total Sperm Concentration (TSC)
Motility (a+b+c)
Rapid Progressive Motility (a)
Slow Progressive Motility (b)
Non-progressive Motility (c)
Immotility (d)
Calculated Normal Morphology
Motile Sperm Concentration (MSC)
Progressive Motile Sperm Concentration (PMSC)
Functional Sperm Concentration (FSC)
Sperm Motility Index (SMI)
Average Velocity
Total Sperm
Motile Sperm
Progressive Motile Sperm
Functional Sperm
Technical Features
Measurement Compartment
|
- Sources of radiant energy - two LEDs for motility and spectrophotometry channels - Detector system - two photo detectors - Motility and Optical Density
|
Sample type
|
- Fresh - Washed - Frozen - Post-vasectomy
|
Specificity
|
- Concentration: 85% - Motility: 80% - Normal morphology (WHO): 65% - High-sensitivity test: 95% motile cells determination
|
Sensitivity
|
- Concentration: 90% - Motility: 85% - Normal morphology (WHO): 85%
|
Visualization Compartment
|
- White LED illumination system - CCD, 330 TV lines - Objective: Standard, x20 - Signal Output: PAL standard - Zoom system for magnification transition between x300 and x500 - Focus regulator
|
|
Displays
|
- Operational backlight LCD (16 lines x 40 characters) - Video backlight LCD (8 x 10 cm)
|
Printer
|
- Built-in, Dot Matrix - 58 mm paper, with 20 characters per line - Ribbon cassette
|
Keypad
|
- Operational keys - Numeric buttons - Cursor buttons - Video control keys
|
Interface
|
- Video output (RCA) - RS-232 cable plug-in
|
Accessories for sample testing
|
- Measuring capillary: Disposable, plastic, syringe loaded for ease of aspirating sample - Standard laboratory microscope slide: depth 20 microns, coverslip 22x22 mm
|
Memory
|
- 500 test results - 500 QC-measurement
|
Operation system
|
- Analysis time: Normal test - 75 seconds, High-sensitivity/Postvasectomy test - 9 minutes (5 minutes in version 2.45 of the SQA-V software) - Software: controls all functions, provides measurement algorithm (according to WHO’99), and provides visual and automatic test performance - Temperature for sample testing: Calibrated for use at room temperature. Motility tests will degrade over time and will vary if the sample is heated - Input signal from motility channel: analog, up to 5V - Input signal from spectrophotometer channel: modulated (1 kHz), analog, up to 5V
|
Quality control
|
- Internal: electronic self- test and auto-calibration. - External: “QwikCheck™beads” quality control material for zero level and concentration.
|
Dimensions
|
- 40 x 30 x 15 cm
|
Weight
|
- 4 kg
|
Power supply
|
- 100 - 250 V AC, 50/60 Hz
|
V-Sperm III Software
Import patient data from the SQA-V to the PC
Run a full semen analysis report with semen images attached
View “Real time” semen samples on the PC screen
Attach video clips to patient files with emphasis on post-vasectomy samples in order to retain visual documentation of the test results for legal purposes
Save patient test results with video clips or still images attached
Edit patient files and add additional manual test results to the data base and report
Save, view and graph patient and control test results
Set the language, select the tests and determine the “normal” ranges for test results
Input security password in order to log-on
System requirements for V-Sperm III Software
| CPU
| 1GHz or better
|
| RAM
| 256 MB
|
| AGP-Video
| Video Board with minimum 16 MB RAM
|
| Monitor
| 15”
|
| Monitor resolution
| Minimum 640 x 480
|
| Color
| 16-bit
|
| HDD
| 200 MB
|
| CD-ROM
| CD-ROM compatible drive
|
| Operating system
| Windows 98/2000/XP, DirectX, DivX
|
| Ports
| RS-232 (serial) and two USB
|
Sample V-Sperm III Test Report
SQA-V Measurement Capillary
1. Motility section
2. Cuvette section
3. Separating Valve
4. Luer Adaptor
5. Syringe
6. Direction Runner
7. Syringe Piston
Filling the capillary

Picture 1

Picture 2

Picture 3
| |
1. Push the syringe piston in fully. Place only thin part of the capillary into the bottom of the sample while angling the sample container at about 45 degrees. (Picture 1)
2. Placing two fingers below the piston head pull the piston back slowly while keeping the tip of the capillary well below the sample level and below any surface bubbles. Continue to aspirate the sample until it appears in the Luer adaptor.
3. Holding the capillary vertically, visually confirm that the sample has completely filled the thin section, the cuvette section and appears in the Luer adaptor. Tap on the syringe to make sure there are no air bubbles in the sample.
4. Quickly (to avoid wicking) and thoroughly wipe the outer surface of the capillary (Picture 2) - both top and bottom - removing all semen from the exterior of the capillary in order to prevent the SQA-V optical chamber from becoming clogged.
4. Slowly and carefully push-in the separating valve until it is level with the plastic (Picture 3). The capillary is now ready to be inserted into one of the SQA-V compartments for testing or viewing.
6. Firmly push the capillary into one of the compartment slots as far as it will go. Ensure that the capillary is properly seated and stable in the compartment - this may require a little extra pressure.
|
SQA-V Technology
Automated Testing System
Step 1: The capillary is inserted into the measurement compartment.
Step 2: Sample concentration is evaluated in the “tall” 10 mm chamber of the capillary by measuring the amount of optical absorption of light as a beam traverses the seminal fluid.
Step 3: Motility is detected in the “thin” 0.3 mm section of the capillary by analyzing light modulations caused by the sperm motion.
Step 4: This information is then digitized and routed to the microprocessor that applies algorithms to extract the required clinical semen parameters.
Motility Channel
Light disturbances caused by moving sperm cells are detected and translated into analog signal peaks.
The greater the number of motile sperm cells in the field of view, the higher the peaks.
The slower the sperm velocity is, the broader the signal peaks will be.
The signals are averaged and translated into MSC (Motile Sperm Concentration).
Concentration Channel
Sperm concentration is measured in the cuvette section of the SQA-V testing capillary.
An infrared light of a specific wavelength that is optimally and specifically absorbed by sperm cells and minimally absorbed by other seminal fluid components is produced by the SQA-V.
In the final calculation of Sperm Concentration, the SQA-V algorithm reads the light absorbed by sperm cells and makes a correction for the light absorbed by the seminal plasma components in order to accurately report sperm concentration.
Visualization System
A standard microscopy slide placed in the SQA-V slide adaptor can be inserted into the video (upper) screen of the SQA-V to view “real time” semen samples.
SQA-V capillaries can also be inserted into this chamber for “scanning” the sample.
Magnification: x300 to x500.
QwikCheck™ Control Material
FDA and CE certified QC, test and treatment kits can be used to liquefy and dilute semen samples, test for pH and leucocytes and provide a known target value for sperm concentration against which laboratories can test the SQA-V calibration, the proficiency of manual sperm counting procedures and the calibration of sperm counting chambers.
QwikCheck™ Beads
Quality control latex beads for testing sperm concentration. For use on both manual and automated systems:
SQA-V
Neubauer hemacytometers
Makler counting chambers
Fixed cover slip chambers (like MicroCell™)
Each kit contains:
3 Levels of QC material: High, Low and Zero
5 ml of each level of QC material
Instructions for use on all types of chambers and automated systems
QwikCheck™ Liquefaction
Used to quickly liquefy viscous semen samples.
Each QwikCheck™ Liquefaction kit contains:
20 single dose, 5 mg vials of lyophilized a-Chymotrypsin
Instructions for use
QwikCheck™ Dilution
Used to dilute semen samples without impacting motility.
Each QwikCheck™ Dilution kit contains:
50 ml of sterile Earl’s Balanced Salt solution
Instructions for use
QwikCheck™ Test Strips
FDA approved semen WBC and pH reagent test strips.
Each QwikCheck™ Test Strip kit contains:
100 test strips
Product insert
SQA IIC-P Sperm Quality Analyzer
Automatic assessment of semen parameters
Useful as a quick, reliable, qualitative fertility screening device
Samples are analyzed, calculated and reported in 45 seconds
High sensitivity motility test for low motility specimens (post vasectomy)
Integrated self-testing and self-calibrating features
Built-in printer provides a paper copy semen analysis report
Application: small and medium-sized clinics, labs and physicians
Parameters tested
Total Sperm Concentration (TSC)
Progressive Motility (a+b)
Normal Morphology
Motile Sperm Concentration (MSC)
Functional Sperm Concentration (FSC)
Sperm Motility Index (SMI)
Total Sperm
Total Motile Sperm
Total Functional Sperm
Technical Features
| Measurement Compartment
| - Source of radiant energy - LED - Detector system - photo detector
|
| Sample type
| - Fresh
|
| Display
| - Operational backlight LCD (4 lines x 40 characters)
|
| Printer
| - Built-in, Dot Matrix
- 58 mm paper, with 20 characters per line
- Ribbon cassette
|
| Keypad
| - 23 button keypad
|
| Accessories for sample testing
| - Measuring capillary: disposable, plastic
|
| Memory
| - Last measurement
|
| Quality control
| - ISO-9002 production, controlled lots, component tracibility, built-in self-test
|
| Dimensions
| - 14 x 36 x 22 cm
|
| Weight
| - 2.7 kg
|
| Power supply
| - 100 - 250 V AC, 50/60 Hz
|
SQA-V compared to SQA IIC-P
| Features
|
SQA IIC-P
|
SQA-V
|
| Total Sperm Concentration (TSC)
|
x
|
x
|
| Motility (a+b+c)
|
|
x
|
| Progresive motility (a+b)
|
x
|
x
|
| Non-progressive motility (c)
|
|
x
|
| Immotility (d)
|
|
x
|
| Calculated Normal Morphology
|
x
|
x
|
| Motile sperm concentration (MSC)
|
x
|
x
|
| Progressive Motile Sperm concentration (PMSC)
|
|
x
|
| Functional sperm concentration (FSC)
|
x
|
x
|
| Sperm Motility Index (SMI)
|
x
|
x
|
| Average Velocity
|
|
x
|
| Total sperm
|
x
|
x
|
| Total motile sperm
|
x
|
x
|
| Total progressively motile sperm
|
|
x
|
| Total Functional sperm
|
x
|
x
|
| Auto-calibration/self-test
|
x
|
x
|
| Built-in printer and keypad
|
x
|
x
|
| Video microscope Visualization
|
|
x
|
| Option to print visual images in test report
|
|
x
|
| Patient archive
|
|
x
|
| PC compatibility with V-Sperm III software
|
|
x
|
| Option to include visual images in the PC report and archive
|
|
x
|
| Option to select morphology criteria (WHO or Kruger)
|
|
x
|
| Option to select specimen type: frozen, washed, etc.
|
|
x
|
SQA-Vb Sperm Quality Analyzers for bulls
Automatic results in 60 seconds
Minimal operator experience or training required
Automatic dosimetry calculations performed for semen extension (as total or motile sperm/insemination)
On-screen visualization of the semen sample on the video screen of the
SQA-Vb or on a PC display (with counting grid and image freezing) using a standard laboratory slide or an SQA-Vb capillary
Variable optical magnification from x300 to x500
A complete semen analysis report can be automatically printed-out
Testing capillary is conveniently used in virtually any testing environment
QC: Self-testing, self-calibrating
PC-compatible with B-Sperm software
- Import patient data from the SQA-Vb to the PC
- Run a full semen analysis report with semen images attached
- View “Real time” semen samples on the PC screen
- Save test results with video clips or still images attached
- Save, view and graph analysis and control test results
Parameters tested:
Total Sperm Concentration (TSC)
Motility
Progressive Motility
Motile Sperm Concentration (MSC)
Progressive Motile Sperm Concentration (PMSC)
Average Velocity
Calculates extension rates for dosimetry
Technical Features
Measurement Compartment
|
- Sources of radiant energy - two LEDs for motility and spectrophotometry channels - Detector system - two photo detectors - Motility and Optical Density
|
Sample type
|
- Fresh - Frozen
|
| Specificity
|
- Concentration: 85% - Motility: 80%
|
| Sensitivity
|
- Concentration: 90% - Motility: 85%
|
| Correlation to Manual Method
|
- Concentration: 0.9 - Motility: 0.85
|
| Visualization Compartment
|
- White LED illumination system - CCD, 330 TV lines - Objective: Standard, x20 - Signal Output: PAL standard - Zoom system for magnification transition between x300 and x500 - Focus regulator
|
| Displays
|
- Operational backlight LCD (16 lines x 40 characters) - Video backlight LCD (8 x 10 cm)
|
| Printer
|
- Built-in, Dot Matrix - 58 mm paper, with 20 characters per line - Ribbon cassette
|
| Keypad
|
- Operational keys - Numeric buttons - Cursor buttons - Video control keys
|
| Interface
|
- Video output (RCA) - RS-232 cable plug-in
|
| Accessories for testing sample
|
- Measuring capillary: plastic, loaded syringe for an easy aspiration of sample - Standard laboratory microscope slide: depth 20 microns, coverslip 22x22 mm
|
| Memory
|
- 500 test results - 500 QC-measurement
|
| Analysis time
|
- 60 seconds
|
| Temperature for sample testing
|
- Calibrated for use at room temperature. Motility tests will degrade over time and will vary if the sample is heated
|
| Signals
|
- Input signal from motility channel: analog, up to 5V - Input signal from spectrophotometer channel: modulated (1 kHz), analog, up to 5V
|
| Quality control
|
- Internal electronic self- test and auto-calibration
|
| Dimensions
|
- 40 x 30 x 15 cm
|
| Weight
|
- 4 kg
|
| Power supply
|
- 100 - 250 V AC, 50/60 Hz
|
| System requirements for B-Sperm Software
|
- CPU 1GHz or better, RAM 256 MB, HDD free space 200 MB, AGP-Video Board with minimum 16 MB RAM, Monitor 15” with minimum resolution 640 x 480 and 16-bit color, CD-ROM drive, Windows 98/2000/XP Operation System, DirectX, DivX, RS-232 two USB ports
|
SQA-Vp Sperm Quality Analyzers for pigs
Automatic results in 60 seconds
Minimal operator experience or training required
Automatic dosimetry calculations performed for semen extension (as total or motile sperm/insemination)
On-screen visualization of the semen sample on the video screen of the SQA-Vp or on a PC display (with counting grid and image freezing) using a standard laboratory slide or an SQA-Vp capillary
Variable optical magnification from x300 to x500
A complete semen analysis report can be automatically printed-out
Testing capillary is conveniently used in virtually any testing environment
QC: Self-testing, self-calibrating
PC-compatible with P-Sperm software
- Import patient data from the SQA-Vp to the PC
- Run a full semen analysis report with semen images attached
- View “Real time” semen samples on the PC screen
- Save test results with video clips or still images attached
- Save, view and graph analysis and control test results
Parameters tested:
Total Sperm Concentration (TSC)
Motile Sperm Concentration (MSC)
Motility Grading
Morphology
Number of motile sperm per ejaculate
Number of total sperm per ejaculate
Technical Features
Measurement Compartment
|
- Sources of radiant energy - two LEDs for motility and spectrophotometry channels - Detector system - two photo detectors - Motility and Optical Density
|
Sample type
|
- Fresh - Frozen
|
| Specificity
|
- Concentration: 90% - Motility: 75% - Morphology: 80%
|
| Sensitivity
|
- Concentration: 90% - Motility: 75% - Morphology: 60%
|
| Correlation to Manual Method
|
- Concentration: 0.9 - Motility: 0.8 - Morphology: 0.7
|
| Precision CV’s
|
- Concentration: 3% - Motility: 5% - Morphology: 5%
|
| Visualization Compartment
|
- White LED illumination system - CCD, 330 TV lines - Objective: Standard, x20 - Signal Output: PAL standard - Zoom system for magnification transition between x300 and x500 - Focus regulator
|
| Displays
|
- Operational backlight LCD (16 lines x 40 characters) - Video backlight LCD (8 x 10 cm)
|
| Printer
|
- Built-in, Dot Matrix - 58 mm paper, with 20 characters per line - Ribbon cassette
|
| Keypad
|
- Operational keys - Numeric buttons - Cursor buttons - Video control keys
|
| Interface
|
- Video output (RCA) - RS-232 cable plug-in
|
| Accessories for testing sample
|
- Measuring capillary: plastic, loaded syringe for an easy aspiration of sample - Standard laboratory microscope slide: depth 20 microns, coverslip 22x22 mm
|
| Memory
|
- 500 test results - 500 QC-measurement
|
| Analysis time
|
- 60 seconds
|
| Temperature for sample testing
|
- Calibrated for use at room temperature. Motility tests will degrade over time and will vary if the sample is heated
|
| Signals
|
- Input signal from motility channel: analog, up to 5V - Input signal from spectrophotometer channel: modulated (1 kHz), analog, up to 5V
|
| Quality control
|
- Internal electronic self- test and auto-calibration
|
| Dimensions
|
- 40 x 30 x 15 cm
|
| Weight
|
- 4 kg
|
| Power supply
|
- 100 - 250 V AC, 50/60 Hz
|
| System requirements for B-Sperm Software
|
- CPU 1GHz or better, RAM 256 MB, HDD free space 200 MB, AGP-Video Board with minimum 16 MB RAM, Monitor 15” with minimum resolution 640 x 480 and 16-bit color, CD-ROM drive, Windows 98/2000/XP Operation System, DirectX, DivX, RS-232 two USB ports
|
SQA-Ve Sperm Quality Analyzers for equines
Automatic results in 60 seconds
Minimal operator experience or training required
Automatic dosimetry calculations performed for semen extension (as total or motile sperm/insemination)
On-screen visualization of the semen sample on the video screen of the SQA-Ve using a standard laboratory slide or an SQA-Ve capillary
Variable optical magnification from x300 to x500
A complete semen analysis report can be automatically printed-out
Testing capillary is conveniently used in virtually any testing environment
QC: Self-testing, self-calibrating
PC-compatible with E-Sperm software
- Import patient data from the SQA-Ve to the PC
- Run a full semen analysis report
- Save, view and graph analysis and control test results
Parameters tested:
Total Sperm Concentration (TSC)
Motility
Progressive Motility
Motile Sperm Concentration (MSC)
Progressive Motile Sperm Concentration (PMSC)
Calculated Normal Morphology
Average Velocity
Technical Features
Measurement Compartment
|
- Sources of radiant energy - two LEDs for motility and spectrophotometry channels - Detector system - two photo detectors - Motility and Optical Density
|
Sample type
|
- Fresh - Washed - Frozen
|
| Specificity
|
- Concentration: 100% - Motility: 96% - Progressive Motility: 90% - Morphology: 93%
|
| Sensitivity
|
- Concentration: 96% - Motility: 95% - Progressive Motility: 90%
|
| Correlation to Manual Method
|
- Concentration: 0.99 - Motility: 0.96 - Progressive Motility: 0.74 - Morphology: 0.89
|
| Visualization Compartment
|
- White LED illumination system - CCD, 330 TV lines - Objective: Standard, x20 - Signal Output: PAL standard - Zoom system for magnification transition between x300 and x500 - Focus regulator
|
| Displays
|
- Operational backlight LCD (16 lines x 40 characters) - Video backlight LCD (8 x 10 cm)
|
| Printer
|
- Built-in, Dot Matrix - 58 mm paper, with 20 characters per line - Ribbon cassette
|
| Keypad
|
- Operational keys - Numeric buttons - Cursor buttons - Video control keys
|
| Interface
|
- Video output (RCA) - RS-232 cable plug-in
|
| Accessories for testing sample
|
- Measuring capillary: plastic, loaded syringe for an easy aspiration of sample - Standard laboratory microscope slide: depth 20 microns, coverslip 22x22 mm
|
| Memory
|
- 500 test results - 500 QC-measurement
|
| Analysis time
|
- 60 seconds
|
| Signals
|
- Input signal from motility channel: analog, up to 5V - Input signal from spectrophotometer channel: modulated (1 kHz), analog, up to 5V
|
| Quality control
|
- Internal electronic self- test and auto-calibration
|
| Dimensions
|
- 40 x 30 x 15 cm
|
| Weight
|
- 4 kg
|
| Power supply
|
- 100 - 250 V AC, 50/60 Hz
|
| System requirements for E-Sperm Software
|
- CPU 1GHz or better, RAM 256 MB, HDD free space 200 MB, AGP-Video Board with minimum 16 MB RAM, Monitor 15” with minimum resolution 640 x 480 and 16-bit color, CD-ROM drive, Windows 98/2000/XP Operation System, DirectX, DivX, RS-232 two USB ports
|
SQA-Vt Sperm Quality Analyzers for turkeys
Automatic results in 60 seconds
Minimal operator experience or training required
Automatic dosimetry calculations performed for semen extension (as total or motile sperm/insemination)
On-screen visualization of the semen sample on the video screen of the
SQA-Vt or on a PC display (with counting grid and image freezing) using a standard laboratory slide or an SQA-Vt capillary
Variable optical magnification from x300 to x500
A complete semen analysis report can be automatically printed-out
Testing capillary is conveniently used in virtually any testing environment
QC: Self-testing, self-calibrating
PC-compatible with T-Sperm software
- Import patient data from the SQA-Vt to the PC
- Run a full semen analysis report with semen images attached
- View “Real time” semen samples on the PC screen
- Save test results with video clips or still images attached
- Save, view and graph analysis and control test results
Parameters tested:
Parameters tested:
Concentration
Millions of sperm cells are analyzed: A very specific wavelength of light is absorbed by the sperm cells in the concentration chamber of the SQA-Vt testing capillary. An optical density detector measures the light absorbed by the cells. This is translated into cell concentration by a microprocessor based on a proprietary MES algorithm.
Motility
Tens of thousands of sperm cells are analyzed as they move through a light source in the SQA-Vt: The movement of motile sperm causes light disturbances. These light disturbances are converted into electronic signals with “peaks and valleys.” These electronic signal peaks are analyzed by a microprocessor and translated into motility based on a proprietary MES algorithm.
Calculates extension rates for dosimetry
Technical Features
Measurement Compartment
|
- Sources of radiant energy - two LEDs for motility and spectrophotometry channels - Detector system - two photo detectors - Motility and Optical Density
|
Sample type
|
- Fresh
|
| Specificity
|
- Concentration: 85% - Motility: 80%
|
| Sensitivity
|
- Concentration: 90% - Motility: 85%
|
| Correlation to Manual Method
|
- Concentration: 0.9 - Motility: 0.85
|
| Visualization Compartment
|
- White LED illumination system - CCD, 330 TV lines - Objective: Standard, x20 - Signal Output: PAL standard - Zoom system for magnification transition between x300 and x500 - Focus regulator
|
| Displays
|
- Operational backlight LCD (16 lines x 40 characters) - Video backlight LCD (8 x 10 cm)
|
| Printer
|
- Built-in, Dot Matrix - 58 mm paper, with 20 characters per line - Ribbon cassette
|
| Keypad
|
- Operational keys - Numeric buttons - Cursor buttons - Video control keys
|
| Interface
|
- Video output (RCA) - RS-232 cable plug-in
|
| Accessories for testing sample
|
- Measuring capillary: plastic, loaded syringe for an easy aspiration of sample - Standard laboratory microscope slide: depth 20 microns, coverslip 22x22 mm
|
| Memory
|
- 500 test results - 500 QC-measurement
|
| Analysis time
|
- 60 seconds
|
| Temperature for sample testing
|
- Calibrated for use at room temperature. Motility tests will degrade over time and will vary if the sample is heated
|
| Signals
|
- Input signal from motility channel: analog, up to 5V - Input signal from spectrophotometer channel: modulated (1 kHz), analog, up to 5V
|
| Quality control
|
- Internal electronic self- test and auto-calibration
|
| Dimensions
|
- 40 x 30 x 15 cm
|
| Weight
|
- 4 kg
|
| Power supply
|
- 100 - 250 V AC, 50/60 Hz
|
| System requirements for T-Sperm Software
|
- CPU 1GHz or better, RAM 256 MB, HDD free space 200 MB, AGP-Video Board with minimum 16 MB RAM, Monitor 15” with minimum resolution 640 x 480 and 16-bit color, CD-ROM drive, Windows 98/2000/XP Operation System, DirectX, DivX, RS-232 two USB ports
|
|